75870-436
|
RAPHAEL Non-Contact Ultrasonic Level
|
25 ft. Cable Length, 0 to 7.5 m (1 to 25 ft) Range, 0.25% of detect range Accuracy |
Each |
|
Retrieving |
|
75870-504
|
RAPHAEL Submersible Hydrostatic Sensor
|
35 ft. Cable Length, 0 – 1 bar (0 to 15 psi) Range, ≤0.5% of span Accuracy |
Each |
|
Retrieving |
|
75870-506
|
RAPHAEL Electric Pressure Sensor
|
16 ft. Cable Length; 0 to 10 bar (0 to 150 psi) Range; ± 0.3% Accuracy |
Each |
|
Retrieving |
|
75870-508
|
RAPHAEL Multi Parameter Sensor
|
10 ft. Cable Length; (Ranges) Active Chlorine: 0.01 to 2.0 mg/L (0.01 to 2.0 ppm) ,Conductivity: 50 to 1,000 µScm-1,Pressure: 0 to 10 bar (0 – 145 psi) ,Temperature: 0°C to 40°C (32°F to 104°F) |
Each |
|
Retrieving |
|
75870-510
|
RAPHAEL Level Switch Sensor
|
20 ft. Cable Length; Max. Working Pressure 10 bar (145 psi) |
Each |
|
Retrieving |
|
75870-462
|
RAPHAEL Turbidity and Temp. Sensor
|
0 to 4000 NTU in 5 Ranges: 0 to 50 NTU; 0 to 200 NTU; 0 to 1000 NTU; 0 to 4000 NTU; 0.01 to 1 NTU - mg/L Resolution; Accuracy <5% of the reading |
Each |
|
Retrieving |
|
75870-464
|
RAPHAEL Conductivity and Temp. Sensor
|
3 m Cable Length; (Ranges) 0 to 200.0μS/cm; 0 to 2000 μS/cm; 0.00 to 20.00 mS/cm; 0.0 to 200.0 mS/cm; Resolution 0.01 to 1 according the range; Accuracy ±1% of the reading |
Each |
|
Retrieving |
|
75870-466
|
RAPHAEL Dissolved Oxygen and Temp. Sensor
|
20 ft. Cable Length; (Ranges) 0.00 to 20.00 mg/L; 0.00 to 20.00 ppm; 0 to 200%; Resolution 0.01 ; Accuracy ±1 mg/L; ±0.1 ppm; ±1% |
Each |
|
Retrieving |
|
75870-468
|
RAPHAEL PH, ORP and Temp. Sensor
|
20 ft. Cable Length; Range pH 0 to 14, Redox -1000 to +1000 mV, 0.00°C á + 50.00°C; Resolution pH 0.01 , Redox 0.1 mV, <0.01°C; Accuracy ±0.1 pH, ±2 mV,±0.5°C |
Each |
|
Retrieving |
|
75870-514
|
RAPHAEL TSS Sensor
|
20 ft. Cable Length; Range 0 to 2,000 ppm to 0 to 50% full scale; Resolution 0.05% of full scale |
Each |
|
Retrieving |
|
75870-516
|
RAPHAEL Rain Gauge Sensor
|
0.01" Resolution; Accuracy ±2% up to 250 mm/hr (10 in./hr); ±3% from 250 to 500 mm/hr; (10 to 20 in./hr) |
Each |
|
Retrieving |
|
75870-520
|
RAPHAEL Non-Contact Radar Level Sensor
|
33 ft. Cable Length; 1 to 20 m (3 to 66') Range; Accuracy ± 2.0 mm (0.08") |
Each |
|
Retrieving |
|
75870-522
|
RAPHAEL Turbidity Optics Sensor
|
Dynamic Range of 0-3000 NTU |
Each |
|
Retrieving |
|
75870-526
|
RAPHAEL Radar Level Sensor
|
33 ft. Cable Length; Range 5 m to 100 m; Accuracy ± 0.25% of max. range |
Each |
|
Retrieving |
|
75870-470
|
RAPHAEL Phycocyanin Optics Sensor
|
— |
Each |
|
Retrieving |
|
75870-472
|
RAPHAEL CDOM/FDOM Optics Sensor
|
— |
Each |
|
Retrieving |
|